Concrete is the one material on a building site that cannot be quietly adjusted once it is in the ground. Order too little and you create a cold joint in the middle of a slab, which is a structural weakness you will live with for the life of the building. Order too much and you pay for a truckload that sets in the skip. Neither mistake is unusual, and both come from the same root cause: the volume was estimated by eye rather than measured.
Volume estimation is not difficult arithmetic. It is a discipline of measuring the right dimensions, keeping the units consistent, and then converting that volume into cement, sand and aggregate using a mix ratio you have actually specified. This guide covers all three steps for slabs, beams, columns, footings and the smaller elements that people forget to add, with worked examples in metric and imperial units.
Every concrete element is a prism of some kind. Slabs are long, wide and thin; beams are long, narrow and deep; columns are tall and square or round. In each case the volume is an area multiplied by a thickness, or a cross-section multiplied by a length.
Two rules avoid most errors:
Measure the finished element, not the formwork. Formwork is built slightly oversize so the concrete can be worked into the corners. If you measure the timber, you will overstate the concrete.
Convert to one unit before multiplying. Mixing metres with millimetres is the single most common arithmetic error in takeoffs. A slab written as "6,000 × 4,500 × 150" is not 6,000 × 4,500 × 150 in metres; it is 6.0 × 4.5 × 0.15.
For any rectangular element:
Volume (m³) = Length (m) × Width (m) × Depth (m)
In imperial units:
Volume (cubic feet) = Length (ft) × Width (ft) × Depth (ft)
To move between them, one cubic metre is 35.31 cubic feet, and one cubic yard is 27 cubic feet. If you work in feet and inches, convert the inches to a decimal fraction of a foot first: 6 inches is 0.5 ft, 4 inches is 0.333 ft, 9 inches is 0.75 ft.
A slab is the easiest element to calculate and the one where thickness errors matter most, because the area is large. Thickness is a design decision, not a guess, but typical domestic values give a sense of the range:
| Slab type | Typical thickness | Notes |
| Domestic floor slab, ground bearing | 100-125 mm | On hardcore and damp-proof membrane |
| Suspended floor slab | 150-200 mm | Needs structural design |
| Garage or driveway slab | 125-150 mm | Reinforcement usually required |
| Light path or hardstanding | 75-100 mm | Rarely reinforced |
| Mix (cement : sand : aggregate) | Typical use | Cement per m³ (50 kg bags) |
| 1 : 1.5 : 3 | Structural columns, suspended slabs | 8.1 |
| 1 : 2 : 4 | General structural, beams, ground slabs | 6.4 |
| 1 : 3 : 6 | Blinding, mass fill, non-structural | 4.4 |